Lithium battery evaluation test project

Lithium battery evaluation test project

definition

Fully charged: To meet the manufacturer's specified calculation capacity, the manufacturer's recommended charging conditions (including current, voltage, temperature,

Charge the battery under time, etc.) Moreover, the time requirement of the battery is within one week after charging.

Complete discharge: in the discharge condition recommended by the manufacturer (including current, temperature, etc.), the battery is discharged according to the specified discharge voltage.

Discharge. And the battery time requirement is within one week after discharge.

Just finished battery: The battery requirements are less than one month after production and are less than XX charge and discharge cycles.

Battery cycle: The battery is continuously charged and discharged according to the manufacturer's recommended conditions, and the discharge capacity of the battery has been specified by the manufacturer.

The calculated capacity has dropped by 40% to 60% .

Indoor temperature: In the test, room temperature means 20± 5 °C This is the temperature in the usual room. This setting is based on

In a simple test environment.

Explosion: An explosion is an internal explosion of the battery or an explosion or damage caused by a crack in the outer casing of the battery.

Fire: A fire is a fire caused by spontaneous combustion or burning inside the battery.

Safety valve operation: Safety valve operation means to exhaust the battery during normal use of the battery (to release the internal pressure of the battery to the outside

Boundary).

Deformation: Deformation refers to the obvious and visible deformation of the battery due to external pressure or internal pressure.

Evaluation test project

( 1 ) Electrical test

Test item charging status battery condition temperature evaluation test method standard

1 . External short circuit fully charged just after the battery is produced 60 °C Passing resistance is less than 50m ¦ ̧ wire is short in two poles

There is no explosion or fire on the road for more than 6 hours.

2 . Forced discharge fully charged just after the production of the normal room temperature according to the manufacturer recommended current forced deep discharge calculation capacity

250% of the amount . * If safety or protection is achieved during the test, the test can be terminated without explosion or fire.

The phenomenon

3 . Continuous charging, complete discharge, just after the normal production of the battery, the normal room temperature is charged according to the manufacturer's recommended method, and the specified electricity

The pressure lasted for 28 days without explosion, no fire, no cracking

4 . Overcharged, fully discharged, just after the normal production of the battery, normal room temperature is charged to the calculated capacity according to the manufacturer's recommended current.

250% . * If the safety or protection function is achieved during the test, the test can be terminated without explosion or fire.

Elephant

5 . High-current charging, complete discharge, just after the normal production of the battery, the normal room temperature is given by the manufacturer's recommended charging current of 3 times.

The battery is charged to more than 100% of the calculated capacity without explosion or fire.

( 2 ) Mechanical performance test

Test item charging status battery condition temperature evaluation test method standard

1 . Vibration fully charged or fully discharged battery freshly produced finished battery vibration normal room temperature in three directions XYZ 90

Up to 100 minutes, the amplitude is 0.8mm The frequency is 10HZ and the rate of change of frequency is 1HZ/min . After the test, put it completely

The battery will be charged to the full capacity recommended by the manufacturer. No explosion, no fire, no deformation

2 . Acceleration fully charged or fully discharged. Just after the battery is produced, the normal room temperature is accelerated in time by 3 millimeters.

In seconds, the average acceleration is 75g (g is the unit of gravity acceleration ) , 125 when reaching the peak -175g . In every XYZ

Vibration in directions perpendicular to each other. After testing, the fully discharged battery will be charged to the manufacturer's recommended capacity. No explosion, no

Has a fire, no deformation

3 . Drop the battery fully charged or fully discharged just after the normal room temperature from 1.9m High place free fall 10 times

On the concrete floor. After testing, the fully discharged battery will be charged to the manufacturer's recommended capacity. No explosion, no fire

Phenomenon ( small battery drop test machine BE-F-320S , Bell brand )

4 . The nail is completely charged through the battery. The battery that has just been produced is normal room temperature with a diameter of 2.5 to 5mm Nail through the electricity

The center axis of the pool * puts the nail into the battery for 6h . No explosion, no fire (battery needle test machine

BE-9002 )

5 . Squeeze the battery that has just been fully charged. Normally room temperature. Place the battery between two flat iron plates to make the vertical axis of the battery.

Parallel to the flat iron plate, the pressure applied to the battery is 13kN without explosion or fire (battery extrusion tester,

BE-6045 )

6 . Impact full charge just finished production of the battery at normal room temperature will be a cylindrical wooden rod (diameter is 7.9mm ) over the electricity

The top of the pool is perpendicular to the cell's longitudinal axis. 9.1kg Quite weight from 61cm The height fell. No explosion, no

The phenomenon of fire (battery impact testing machine BE-6045 )

7 . 10m Drop completely charged just after the finished battery is normal room temperature from 10m High place to drop the battery to the water

On the mud floor. No explosion, no fire

( 3 ) Environmental performance test

Test item charging status battery condition temperature evaluation test method standard

1 . High temperature storage fully charged just after production of the battery ( a ) at temperature 100 °C The battery is stored in the oven for 5 hours.

Placed at temperature 20 °C Place 24h(b) in 60 °C Place the battery in the oven after 30 days of storage 20 °C of

There is no explosion and no fire in the place for 24 hours.

2 . The heat conflict is fully charged. The battery that has just been produced has passed through 10 consecutive cycles in 2 hours. -20 °C And 40

°C to remove the battery from -20 °C Move to 60 °C Place, and the replacement time did not explode within 5 minutes, no fire, no

Damaged, no deformation

3 . Low-voltage fully charged battery that has just been produced at room temperature. When the battery is placed at an absolute pressure equal to or less than 11.6kpa ,

There was no explosion or fire at 6 hours.

( 3 ) II environmental performance test (illegal behavior)

Test item charging status battery condition temperature evaluation test method standard

4 . The heat is warmed up and fully charged. Just after the finished battery, put the battery into the oven to 5± 2 °C / min rate heating up to 130

°C. Place the battery in the oven for about 60 minutes. No explosion, no fire

5 . Drop into the water, fully charged, just after the battery is produced, immerse the battery in water (room temperature) for 24 hours without explosion.

Fried, no fire phenomenon __

In the Diagnostics devices category, we have put together a comprehensive selection of products that support the determination of a reliable diagnosis, from diagnostic instruments for monitor vital signs like Sphygmomanometer, mercuric or Digital Thermometer, Weight Scale with height measuring, Stethoscopes to ETN diagnostic devices, such as Audio tester Sound gear ,Tuning fork with wood base, Pupil pen light and Nasal specula. Also in this category, you will find Reflex  hammer, Alcohol tester and Blood Glucose Tester .

 

And other Medical diagnostic and monitor instruments such as   ECG Machine , Patient Monitoring, Fetal Doppler will be described in the category of Medical Instruments.

Diagnostic Devices

Diagnostic Devices,Engine Diagnostic Device,Mini Diagnostic Devices,Personal Diagnostic Devices

NINGBO YINGMED MEDICAL INSTRUMENTS CO.,LTD , https://www.chinayingmed.com

Posted on