Hospital Medical Newborn Infant Radiant Warmer IW-6b
INFANT WARMER IW-6A with breath resuscitation bag, infant head fix unit, oxygen supplying set include low pressure aspirator, oxygen cylinder, regulator
Three control mode: Pre-warm mode control, manual mode control and baby mode control by micro-computer
Set temperature and baby temperature can be displayed separately
Horizon angle of warmer module and inclination of the bassinet can be adjusted
The panels around bassinet can be turned outward
X-ray cassette under the bassinet
APGAR timer
Timer to count phototherapy time
Failure alarm indication, RS232 connector
Hospital Medical Newborn Infant Radiant Warmer :Â
Power supply | AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Maximum Power output | 700VA |
Three control mode | Pre-warm mode control, manual mode control and baby mode control by micro-computer |
Baby mode temperature control range |  34.5-37.5°C |
Temperature sensor display range | 5-65°C |
Accuracy of skin temperature sensor |  ±0.3°C |
Temperature uniformity of mattress |  ≤2°C |
Angle of warmer module | 0°, 30°, 60° for two days |
Inclination of the bassinet |  ±10° |
APGAR timer |  it will give sound when the unit is tones at 1', 5', 10' |
Failure alarm |  over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on |
Wave length of blue light |  420-470nm |
Operating range |  18°C-30°C |
Ambient air movement rate |  ≤0.3m/s |
Packing |  each unit is packed into one carton |
Dimension | Â 127cmX82cmX113.5cm |
Gross Weight |  100Kg |
IW-6A Standard Configuration:
The warmer module, the bassinet, the main column, the mobile stand, the controller, the I.V. Pole and the tray,
with the phototherapy unit, and the Beath resuscitation bag, Infant head fixing unit, the oxygen supplying set
(Low-pressure aspirator, the oxygen cyliders, buoy type oxygen regulator, wall type oxygen regulator)
Optional Configuration: VHA stand, drawer, Baby sca
Hospital Medical Newborn Infant Radiant Warmer IW-6b
INFANT WARMER IW-6A with breath resuscitation bag, infant head fix unit, oxygen supplying set include low pressure aspirator, oxygen cylinder, regulator
Three control mode: Pre-warm mode control, manual mode control and baby mode control by micro-computer
Set temperature and baby temperature can be displayed separately
Horizon angle of warmer module and inclination of the bassinet can be adjusted
The panels around bassinet can be turned outward
X-ray cassette under the bassinet
APGAR timer
Timer to count phototherapy time
Failure alarm indication, RS232 connector
Hospital Medical Newborn Infant Radiant Warmer :Â
Power supply | AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Maximum Power output | 700VA |
Three control mode | Pre-warm mode control, manual mode control and baby mode control by micro-computer |
Baby mode temperature control range |  34.5-37.5°C |
Temperature sensor display range | 5-65°C |
Accuracy of skin temperature sensor |  ±0.3°C |
Temperature uniformity of mattress |  ≤2°C |
Angle of warmer module | 0°, 30°, 60° for two days |
Inclination of the bassinet |  ±10° |
APGAR timer |  it will give sound when the unit is tones at 1', 5', 10' |
Failure alarm |  over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on |
Wave length of blue light |  420-470nm |
Operating range |  18°C-30°C |
Ambient air movement rate |  ≤0.3m/s |
Packing |  each unit is packed into one carton |
Dimension | Â 127cmX82cmX113.5cm |
Gross Weight |  100Kg |
IW-6A Standard Configuration:
The warmer module, the bassinet, the main column, the mobile stand, the controller, the I.V. Pole and the tray,
with the phototherapy unit, and the Beath resuscitation bag, Infant head fixing unit, the oxygen supplying set
(Low-pressure aspirator, the oxygen cyliders, buoy type oxygen regulator, wall type oxygen regulator)
Optional Configuration: VHA stand, drawer, Baby sca
Tattoo Machines Kits,Eyebrows Tattoo Machine,Makeup Kit
Taomore Trading Co., Ltd. , http://www.szttattoo.com