The water to be treated by the filter enters the body through the water inlet, and impurities in the water are deposited on the stainless steel filter screen, thereby generating a pressure difference. The differential pressure switch monitors the pressure difference between the inlet and outlet. When the pressure difference reaches the set value, the electric controller sends the hydraulic control valve and drives the motor signal, triggering the following actions: the motor drives the brush to rotate, the filter element is cleaned, and the control valve is opened. For the sewage discharge, the entire cleaning process only lasts for several tens of seconds. When the cleaning is finished, the control valve is closed, the motor stops rotating, the system returns to its initial state, and the next filtration process begins.
After the equipment is installed, the technician will debug and set the filtration time and cleaning conversion time. The water to be treated enters the body through the water inlet, and the filter starts to work normally. When the preset cleaning time is reached, the electric controller gives the hydraulic control valve. Driving the motor signal, triggering the following actions: the motor drives the brush to rotate, and the filter element is cleaned. At the same time, the control valve is opened for sewage discharge. The entire cleaning process only lasts for several tens of seconds. When the cleaning is finished, the control valve is closed and the motor stops rotating. The system returns to its initial state and begins the next filtration process.
The inside of the filter casing is mainly composed of a coarse filter mesh, a fine filter mesh, a suction pipe, a stainless steel brush or a stainless steel nozzle, a sealing ring, an anti-corrosion coating, a rotating shaft and the like.
Features
10.1 inch high resolution color TFT display
Lightweight and portable design suitable for Ambulance,Emergency Transport
Three Working Modes : Monitoring , Surgery and Diagnosis.
Simple and friendly operating display interface.
Multi-display modes suitable for different applications: Standard Interface , Large font , ECG Standard Full Display ,OXY, Trend able BP Trend.
Built-in high capacity battery up to 3 hours of continuous work
Technique Specification
ECG
Lead Mode : 5 Leads ( I , ll , Ill , AVR , AVL , AVF , V )
Gain : 2.5mm / mV, 5.0mm /mV , 10mm /Mv, 20mm /mV
Heart Rate : 15-300 BPM ( Adult ) ; 15-350 BPM ( Neonatal )
Resolution : 1 BPM
Accuracy : ± 1%
Sensitivity > 200 uV ( Peak to peak )
ST measurement range : -2.0 ~+ 2.0 Mv
Accuracy : -0. 8mV~+ 0. 8mV : ± 0. 02mV or ± 10% , which is greater
Other Range : unspecified
Sweep speed : 12.5 mm / s , 25mm / s , 50mm / s
Bandwidth:
Diagnostic : 0.05~130 Hz
Monitor : 0.5~40 Hz
Surgery : 1~20 Hz
SPO2
Measuring Range : 0 ~ 100%
Resolution : 1%
Accuracy : 70%~100% ( ± 2 % )
Pulse Rate : 20-250 BPM
Resolution : 1 BPM
Accuracy : ± 3 BPM
Optinal Parameters :
Central monitoring system
Dual IBP
Etco 2
12-lead ECG
Nellcor SpO2
Sun Tech NIBP
NIBP
Method : Oscillometry
Measure mode Manual, Auto, STAT
Unit : mmHg , kPa
Measure and alarm range:
Adult Mode
SYS 40 ~ 280 mmHg
DIA 10 ~ 225 mmHg
MEAN 20 ~ 240 mmHg
Pediatric Mode
SYS 40 ~ 220 mmHg
DIA 10 ~ 160 mmHg
MEAN 20 ~ 170 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution : 1 mmHg
Accuracy : ± 5 mmHg
TEMP
Measure and Alarm Range : 0 ~ 50 C
Resolution : 0 . 1C
Accuracy : ± 0 . 1C
Standard Parameters
ECG, RESP, TEMP, NIBP, SPO2, PR
RESP
Method : Impedance between RA-LL or RALA
Measurement Range:
Adult : 10~120 BrPM
Neonatal / Pediatric : 7~150 BrPM
Resolution : 1 BrPM
Accuracy : ± 2 BrPM
Standard Configuration
No Item Qty
- 1 Main Unit 1
- 2 5-lead ECG cable 1
- 3 Disposable ECG Electrode 5
- 4 Adult Spo2 probe 1
- 5 Adult NIBP cuff 1
- 6 NIBP extension tube 1
- 7 Temperature probe 1
- 8 Power Cable 1
- 9 User Manual 1
- 10 Fuse 3