1. Gel & Clot Activator Tube
Gel and clot activator tube is used for blood serum biochemistry, immunology and drug testing, etc. There uniformly sprays the coagulant on the surface inside the tube, which will greatly shorten the clotting time. As the imported separation gel from Japan is pure substance, very stable in physicochemical property, it can well stand high-temperature so that the gel will maintain a stable status during the storage and transportation process. The gel will get solidified after centrifugation and completely separate serum from fibrin cells just like a barrier, which effectively prevents the substance exchange between blood serum and cells. Serum collection efficiency is improved and high-quality serum will be obtained, thus it comes to more authentic testing result. Keep the serum stable for more than 48 hours, no obvious change will happen on its biochemical features and chemical compositions, then the tube could be directly used in sampling analyzers.
- Time for complete clot retraction: 20-25min
- Centrifugation speed: 3500-4000r/m
- Centrifugation time: 5min
- Recommended storage temperature: 4-25ºC
Item No. |
Spec. |
Volume |
Additive |
Color | Qty/Cs(Glass) |
Qty/Cs(PET) |
|
KJ030AS |
Φ13×75mm |
3ml |
Gel & Clot Activator |
Yellow | 1800 |
1800 |
|
KJ040AS |
Φ13×75mm |
4ml |
Gel & Clot Activator |
Yellow | 1800 |
1800 |
|
KJ0501AS |
Φ13×100mm |
5ml |
Gel & Clot Activator |
Yellow | 1200 |
1800 |
|
KJ0601AS |
Φ13×100mm |
6ml |
Gel & Clot Activator |
Yellow | 1200 |
1800 |
|
KJ0701AS |
Φ16×100mm |
7ml |
Gel & Clot Activator |
Yellow | 1200 |
1200 |
|
KJ0801AS |
Φ16×100mm |
8ml |
Gel & Clot Activator |
Yellow | 1200 |
1200 |
|
KJ0901AS |
Φ16×100mm |
9ml |
Gel & Clot Activator |
Yellow | 1200 |
1200 |
2. No Additive Tube
No additive tube is used in blood collection and storage for biochemistry, immunology, serology, test of various kinds of virus and microelement in medical inspection. With special treatment of the inner surface, it's extremely smooth for normal activity of thrombocyte and unhindered clotting, which prevents hemolysis or adhesion of blood corpuscle or fibrin to the inner surface. It can provide enough pollution-free serum samples for clinical test, and maintain the normal compositions of serum for a long time. Moreover, it's helpful to serum reinspection with good repeatability.
Time for complete clot retraction: 1.5-2h
Centrifugation speed: 3500-4000r/m
Centrifugation time: 5min
Recommended storage temperature: 4-25ºC
Item No. |
Specification |
Volume |
Additive |
Qty/PK(Glass) |
|
||
KJ030A |
Φ13×75mm |
3ml |
No |
1800 |
1800 |
||
KJ040A |
Φ13×75mm |
4ml |
No |
1800 |
1800 |
||
KJ050A |
Φ13×75mm |
5ml |
No |
1800 |
1800 |
||
KJ0501A |
Φ13×100mm |
5ml |
No |
1200 |
1800 |
||
KJ0601A |
Φ13×100mm |
6ml |
No |
1200 |
1800 |
||
KJ0701A |
Φ13×100mm |
7ml |
No |
1200 |
1800 |
||
KJ0801A |
Φ16×100mm |
8ml |
No |
1200 |
1200 |
||
KJ0901A |
Φ16×100mm |
9ml |
No |
1200 |
1200 |
||
KJ1002A |
Φ16×100mm |
10ml |
No |
1200 |
1200 |
3. Clot Activator Tube
Clot activator tube is used in the blood collection for biochemistry and immunology in medical inspection. It is suitable for wide range of operating temperature. With special treatment, the tube inner surface is very smooth where high-quality coagulant sprays uniformly. The blood sample will completely contact with coagulant and clot within 5-8min. High-quality serum thus is obtained by later centrifugation, free from the cracking of blood corpuscle, hemolysis, separation of fibrin protein, etc. Hence the serum can meet the requirements of fast clinic and emergency serum test.
- Time for complete clot retraction: 20-25min
- Centrifugation speed: 3500-4000r/m
- Centrifugation time: 5min
- Recommended storage temperature: 4-25ºC
Item No. |
Specification |
Volume |
Additive |
Qty/PK(Glass) |
Qty/PK(PET) |
KJ030Z |
Φ13×75mm |
3ml |
Clot Activator |
1800 |
1800 |
KJ040Z |
Φ13×75mm |
4ml |
Clot Activator |
1800 |
1800 |
KJ050Z |
Φ13×75mm |
5ml |
Clot Activator |
1800 |
1800 |
KJ0501Z |
Φ13×100mm |
5ml |
Clot Activator |
1200 |
1800 |
KJ0601Z |
Φ13×100mm |
6ml |
Clot Activator |
1200 |
1800 |
KJ0701Z |
Φ13×100mm |
7ml |
Clot Activator |
1200 |
1800 |
KJ0801Z |
Φ16×100mm |
8ml |
Clot Activator |
1200 |
1200 |
KJ0901Z |
Φ16×100mm |
9ml |
Clot Activator |
1200 |
1200 |
KJ1002Z |
Φ16×100mm |
10ml |
Clot Activator |
1200 |
1200 |
4. Heparin Tube
Heparin tube is used in blood collection for the test of clinical plasma, emergency biochemistry and blood rheology, etc. With little interference on blood compositions and no influence upon the erythrocyte size, it won't cause hemolysis. Besides, it has the features of quick plasma separation and wide range of operating temperature as well as high compatibility with serum index. The anticoagulant heparin activates fibrinolysin, while restraining the thromboplastin, and then achieves the dynamic balance between fibrinogen and fibrin, free of fibrin thread in the inspection process. Most of the plasma indexes can be repeated within 6 hours. Lithium heparin not only has the features of sodium heparin, but also can be used in themicroelements test with no effect on sodium ion. To meet various need of clinical laboratory, KANGJIAN can add plasma separation gel for making high-quality plasma.
- Centrifugation speed: 3500-4000 r/m
- Centrifugation time: 3min
- Recommended storage temperature: 4-25ºC
Item No. |
Specification |
Volume |
Additive |
Qty/PK(Glass) |
Qty/PK(PET) |
KJ030SH |
Φ13×75mm |
3ml |
Heparin Sodium |
1800 |
1800 |
KJ040SH |
Φ13×75mm |
4ml |
Heparin Sodium |
1800 |
1800 |
KJ050SH |
Φ13×75mm |
5ml |
Heparin Sodium |
1800 |
1800 |
KJ0701SH |
Φ13×100mm |
7ml |
Heparin Sodium |
1200 |
1800 |
KJ1002SH |
Φ16×100mm |
10ml |
Heparin Sodium |
1200 |
1200 |
KJ030LH |
Φ13×75mm |
3ml |
Heparin Lithium |
1800 |
1800 |
KJ040LH |
Φ13×75mm |
4ml |
Heparin Lithium |
1800 |
1800 |
KJ050LH |
Φ13×75mm |
5ml |
Heparin Lithium |
1800 |
1800 |
KJ0701LH |
Φ13×100mm |
7ml |
Heparin Lithium |
1200 |
1800 |
KJ1002LH |
Φ16×100mm |
10ml |
Heparin Lithium |
1200 |
1200 |
5. PT Tube
       PT tube is used for blood coagulation test and applicable to fibrinolytic system(PT,TT, APTT and fibrinogen, etc. ). The mixing ratio is 1 part citrate to 9 parts blood. Accurate ratio can guarantee effectiveness of the testing result and avoid misdiagnosis. As the sodium citrate has very little toxicity, it is also used for blood storage. Do draw sufficient blood volume to ensure accurate testing result. PT tube with double-deck is with little dead space, Which can be used to monitor the test of vWF, FVIII,platelet functions, Heparin therapy.
Item No. |
Specification |
Volume |
Additive |
Color | Qty/PK(Glass) |
Qty/PK(PET) |
KJ018NC |
Φ13×75mm |
1.8ml |
3.2% Sodium Citrate |
Blue | 1800 |
1800 |
KJ027NC |
Φ13×75mm |
2.7ml |
3.2% Sodium Citrate |
Blue | 1800 |
1800 |
KJ036NC |
Φ13×75mm |
3.6ml |
3.2% Sodium Citrate |
Blue | 1800 |
1800 |
KJ045NC |
Φ13×75mm |
4.5ml |
3.2% Sodium Citrate |
Blue | 1800 |
1800 |
KJ018NCD | Φ13×75mm |
1.8ml |
3.2% Sodium Citrate |
Blue | -- |
1800 |
KJ027NCD | Φ13×75mm |
2.7ml |
3.2% Sodium Citrate |
Blue | -- | 1800 Â |
6. Glucose Tube
Glucose tube is used in blood collection for the test such as blood sugar, sugar tolerance, erythrocyte electrophoresis, anti-alkali hemoglobin and lactate. The added Sodium Fluoride effectively prevents metabolism of blood sugar and Sodium Heparin successfully solves the hemolysis. Thus, the original status of blood will last for long time and guarantee stable testing data of blood sugar within 72 hours. Optional additive is Sodium Fluoride+Sodium Heparin, Sodium Fluoride+ EDTA.K2, Sodium Fluoride+EDTA.Na2.
- Centrifugation speed: 3500-4000 r/m
- Centrifugation time: 5min
- Recommended storage temperature: 4-25 ºC
Item No. |
Specification |
Volume |
Additive |
Qty/PK(Glass) |
Qty/PK(PET) |
KJ020FX |
Φ13×75mm |
2ml |
Sodium Fluoride+Sodium Heparin |
1800 |
1800 |
KJ030FX |
Φ13×75mm |
3ml |
Sodium Fluoride+Sodium Heparin |
1800 |
1800 |
KJ040FX |
Φ13×75mm |
4ml |
Sodium Fluoride+Sodium Heparin |
1800 |
1800 |
KJ050FX | Φ13×75mm |
5ml | Sodium Fluoride+Sodium Heparin |
1800 | 1800 |
KJ0301FX |
Φ13×100mm |
3ml |
Sodium Fluoride+Sodium Heparin |
1200 |
1800 |
KJ0401FX |
Φ13×100mm |
4ml |
Sodium Fluoride+Sodium Heparin |
1200 |
1800 |
KJ0501FX |
Φ13×100mm |
5ml |
Sodium Fluoride+Sodium Heparin |
1200 |
1800 |
KJ0601FX |
Φ13×100mm |
6ml |
Sodium Fluoride+Sodium Heparin |
1200 |
1800 |
7. EDTA Tube      Â
EDTA tube is widely used in clinical haematology, cross matching, blood grouping as well as various kinds of blood cell test instruments. It offers a comprehensive protection for blood cell, especially for protecting the blood platelet, so that it can effectively stop the gathering of blood platelet and makes the form and volume of blood cell uninfluenced within a long time. Excellent outfits with super-minute technique can spray additive uniformly on the inner surface of the tube, thus blood specimen can completely mix with the additive. EDTA anticoagulant plasma is used for biological assay of pathogenic microorganism, parasite and bacterial molecule, etc.
Item No. |
Specification |
Volume |
Additive |
Qty/PK(Glass) |
Qty/PK(PET) |
KJ010K2E |
Φ13×75mm |
1ml |
EDTA.K2 |
1800 |
1800 |
KJ020K2E |
Φ13×75mm |
2ml |
EDTA.K2 |
1800 |
1800 |
KJ030K2E |
Φ13×75mm |
3ml |
EDTA.K2 |
1800 |
1800 |
KJ040K2E |
Φ13×75mm |
4ml |
EDTA.K2 |
1800 |
1800 |
KJ050K2E |
Φ13×75mm |
5ml |
EDTA.K2 |
1800 |
1800 |
KJ0501K2E |
Φ13×100mm |
This classification summarizes the Organic Spirulina Tablets produced by our own factory in northwestern of China .
We have advanced equipment and strict quality control system to ensure the quality and production.
The products under the classification are: 1. Organic Spiruina Tablets .
Various parameter specifications of our product:
Naturland Certified ; CERES certified .
About Company Organic Spirulina Tablets Organic Spirulina Tablets,High Protein Spirulina Tablet,Spirulina Tablets Food Grade,Natural Spirulina Tablets YANCHI YI JIAN BIOLOGICAL PROJECT CO.,LTD , http://www.spirulina-yj.com |