Model NO.: S1100B
Anesthesia: Semi Closed
Type of Operating Light: Double Operating Light
Medical Device Regulatory Type: Type 3
OEM: Yes
Application: ICU and Operation Room
Trademark: Superstar
Transport Package: Wooden Case
Specification: L560*W 560*H 605mm; 670*700*1160mm
Origin: China
HS Code: 9019200000
 Application
The ventilator makes a good performance in operation room,ICU department and emergency treatment.It used to assist or replace the spontaneous breathing for adult pediatric and neonatal more than 2kg. 25 years experience in Market-oriented ventilator make us professional and reliable, satisfying all your needs in ventilation. Due to the flexible configuration, good quality and competitive price, S12 has soon become the superstar of market.Features
A.15"Â TFT touch screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
B..Multiple ventilation modes,suitable for ICU,emergency department and operation room etc: ( IPPV, A/C, PCV, SIMV,PSV, SPONT/CPAP,SIGH,MANUAL)
C.5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
D.ETCO2 is standard configuration for this machine.Â
E.Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
F.Rapid oxygen supply,automatically offer high flow rate oxygen within two minutes
G.Nebulization make medicine into small liquid and particle,easier and quickier for patient to breathe in.
H.High temperature resistance breathing circuit is reusable and anti-pollution.
Safety
A.14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
B.Built-in oxygen concentration sensor, ensure stable precision of  oxygen concentration.
C.Easy to move with four casters, easy to stop with two brakes.
D.Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
E.Compact long life internal battery can provide emergency power,avoid risk of patient.
F.Self-check before operation,eliminate system mistake.
Specifications
Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV |
Ventilator parameter ranges | Â |
Tidal volume(Vt) | 0 ~ 2000mL |
Frequency (Freq) Oxygen concentration |
1bpm ~ 100 bpm 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | Â |
Frequency (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration |
0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration |
15 % ~ 100 % Â |
Oscillographs display: |  |
P-T(pressure - time) | Â |
F-T(flow - time) | Â |
P-V loop (pressure - volume loop) | Â |
V-T(volume - time ) | Â |
ETCO2-T (End-tidal CO2 - time) | Â |
 |  |
Alarms and protection |  |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm |
5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm |
20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit |
                5-60s Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
 |  |
Working conditions | Â |
Gas source | O2, AIR |
Pressure | 280kPa-600kPa |
Voltage | ~220V±22V |
Power frequency | 50Hz ± 1Hz |
Input power |
900VAÂ (with air compressor) 250VAÂ (without air compressor) |
Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV |
Ventilator parameter ranges | Â |
Tidal volume(Vt) | 0 ~ 2000mL |
Frequence (Freq) Oxygen concentration |
1bpm ~ 100 bpm 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | Â |
Frequence (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration |
0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration |
15 % ~ 100 % Â |
Graphical display: | Â |
P-T(pressure - time) | Â |
F-T(flow - time) | Â |
P-V loop (pressure - volume loop) | Â |
V-T(volume - time ) | Â |
ETCO2-T (End-tidal CO2 - time) | Â |
 |  |
Alarm and protection | Â |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm |
5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm |
20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit |
                5-60s Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
 |  |
Working conditions | Â |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | ~220V ±22V |
Power frequency | 50Hz ± 1Hz |
Input power |
900VAÂ (with air compressor) 250VAÂ (without air compreesor) |