H-3000 Neonatal & Fetal Care Baby Infant Incubator

  • Model NO.: H-3000
  • Certification: CE, ISO13485
  • Group: Infant
  • Medical Devices Reg./Record No.: Gsyjxz20123540587
  • Airtemp Control Range: 20°c~37°c
  • Mattress Tray Size: 630×360 Mm
  • Skin Temp Sensor Accuracy: ≤0.3°c
  • Noise Level Within Hood Environment: ≤55db
  • Packing Size: 100×58×80 Cm(2 Cartons) 120kgs
  • Transport Package: Carton
  • Origin: China
  • Theory: Infant Incubator
  • LCD Display: Without LCD Display
  • Medical Device Regulatory Type: Type 2
  • Temperature Control Mode: Air and Skin Servo Control
  • Operate Port: 6 (2 Iris Ports)
  • Skintemp Control Range: 30°c~37°c
  • Humidity Display Range: 5%~99%
  • RS-232connector: Yes
  • Trademark: Healicom
  • Specification: CE, ISO
  • HS Code: 90189090
H-3000 Infant Incubator
H-3000 Neonatal & Fetal Care Baby Infant Incubator
 
STANDARD COMPOSITION
1. Servo Control Mode: air temperature, skin temperature;
2. Instant Parameter Displaying: set temp, air temp ,skin temp, internal humidity ,heat power rate;
3. Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air& skin temp override, fan failure, system failure;
4. >37°C Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function;
5. RS-232 Output Connector (Use for network system )

 

Specification:

Power

Model H-3000-1E

110 / 120 V ac, 50Hz / 60Hz

Model H-3000-2E

220 / 240 V ac, 50Hz / 60Hz

Power Input

≤400VA

Refer to IEC60601-1, this equipment belongs to ClassI, Type BF 

Its operation is continuous

Alarm

Power Alarm

Power Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle

Fan Alarm 

Fan Failure: Activates if Fan motor malfunctions

Sensor Alarm

Air Sensor Failure: Air Sensor malfunction, refer unit to service

Sensor Out of Position: Activated when Sensor is not in correct position to perform calibration or continue operation

Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller

Skin Sensor Failure: Activated when Skin Sensor malfunctions

Deviation Alarm

High Air Temperature: Activated if displayed Air Temperature is 15°C above set point

Low Air Temperature: Activated if displayed Air Temperature is 25°C below set point

High Skin Temperature: Activated if displayed Skin Temperature is 10°C above set point

Low Skin Temperature: Activated if displayed Skin Temperature is 10°C below set point

Over Temperature Alarm

Over Air Temperature: Activated when displayed Air Temperature was approach 38°C for set temperature ≤37°C, or approach 40°C for set temperature >37°C in Air Mode

Over Skin Temperature: Activated when displayed Skin Temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C in Skin Mode

System Alarm

System Failure: Activated if Temperature Control System malfunctions

Temperature Control Range and Correlative Specifications

Air Temperature

20°C~37°C,for set temperature ≤37°C, 37°C~39°C, for set temperature >37°C

Skin Temperature

20°C~37°C,for set temperature ≤37°C, 37°C~38°C, for set temperature >37°C

Temperature Rise Time

≤30min

Temperature Variability

±0.5°C

Temperature Uniformity

≤1°C

Skin Sensor Precision

≤0.3°C

Humidity

Humidity Display Range

5%RH~99%RH

Environment Requirement

Environment Temperature

Operation Temperature Range

+20°C~+30°C

Store Temperature Range

-40°C~+55°C

Environment Humidity

Operation Humidity Range

30%~75%

Store Humidity Range

10%~100%

Atmospheric Pressure Range

700hPa~1060hPa

Other

Specifications

Noise Level Within Hood Environment

≤55dB(Environment noise below 45dB)

Carbon Dioxide (CO2) Level within the Hood

Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress

Air Velocity Over Mattress

less than 0.3m/s

Infant Bed Max Load

10kg

Transfusion Shelf Max Load

2kg

Cabinet Max Load

6kg

Function of "SILENCE" Key

Make the alarm to be silence for 10 minutes by press this key

Deviation Alarm

Sensor Alarm

Fan Alarm

Factory Default Settings

Temperature Control Mode Air Temperature Mode

Air Set Temperature: 32°C

Skin Set Temperature: 34°C

Temperature Units:°C

NOTE: Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperature.